Brand Name: LYTTE or LUTE
Model Number: LTWF
Place of Origin: Shandong, China (Mainland)
LTWF Series Modular Scroll Air Cooled Chiller, Air to Water Chiller, Industrial Chiller
CE CRAA ISO Certificate Air Cooled Chiller,Air to Water Chiller,Air Cooled Water Chiller,Industrial Chiller with Copeland,Hitachi,Sanyo,Danfoss Scroll Compressor for Cooling Only in Building,Factory,etc
INTRODUCTION:
A. With scroll, or recipocating compressor of high quality, high efficient heat exchangers, excellent system design, by excllent process, the chillers is of suffient capacity and efficiency.
B. The chillers will work stably for long time period as they are produced by excllent process, composed of reliable control components and professional control procedure.
C. Complete safety protection:
1.High&low pressure protection, pressure safety value protection;
2.Overload protection to the compressor;
3.Power supply protect for phase lack, counter phase, voltage too high and voltage deficient;
4.Water system protection for freezing breaking, water lack etc.
FEATURE
1. Ready to work only after connected to chilled water system;
2. A stainless steel water vessel,a low noise pump have been fixed inside the chiller;
3. With energy saving fan of large air flow and low noise;
4. The chillers of capacity below 50KW is movable by wheels with them;
5. The chillers of capacity over 50KW are double refrigeration system design that is good to reduce the frequent start and stop for load change. The chillers can run even 1 system is in trouble.
6. Strict test and inspection has been made before the chillers are delivered.
Model Specifications: LTWF-68 A S E(P)
LT-LVTE Company Products Code
W-Scroll Type Compressor
F-Air Cooled Type Chiller
E-Built in Water Pump and Water Vessel; P-Built in Water Pump without Vessel; Empty-No Pump and Vessel
System Diagram
Model Details of Air Cooled Chiller
1. Design Cooling Condition: Chilled Water In/Out 12°C/7°C;Ambient 35°C
Models: LT03AS-40AD Cooling Capacity: 8KW-120KW
-Hermetic Scroll Compressors
-Tube in Tube Type Heat Exchanger for Evaporator
-V Type Fin Air Cooled Condenser
-Water Pump and Water Tank are an optional to built in the chiller
-Chilled Water Inlet/Outlet Temperature 12°C/7°C,Ambient 35°C
-Mostly Used for Central Air Conditioning Cooling
Remark: 1.Colling Condition: Chilled water in/out 12/7°C;Ambient Temperature 35°C;
2. Suitable chilled water temperature: 7-25°C;
3. Power supply: 3P-380V-50HZ; with voltage allowance ±10%, voltage dif between the phase lines±2%;
4.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;
5. There may be Changes for improvement without notice, confirm always before your order.
Remark: 1.Colling Condition: Chilled water in/out 12/7°C;Ambient Temperature 35°C;
2. Suitable chilled water temperature: 7-25°C;
3. Power supply: 3P-380V-50HZ; with voltage allowance ±10%, voltage dif between the phase lines±2%;
4.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;
5. There may be Changes for improvement without notice, confirm always before your order.
Low Temperature Models:
2.Cooling Condition: Chilled Glycol in/out -1/-5°C; ambient 35°C
Models: LT03ASL-40ADL Cooling Capacity: 4.7KW-61.6KW
-Hermetic Scroll or Semi-hermetic Piston Compressors
-Tube in Tube Type Heat Exchanger for Evaporator
-V Type Fin Air Cooled Condenser
-Water Pump and Water Tank are an optional to built in the chiller
-Chilled Glycol Inlet/Outlet Temperature -1°C/-5°C, Ambient 35°C
-Mostly Used for Industrial Processing Cooling
Remark:1.Designed Condition:Chilled Glycol in/out -1/-5°C; ambient 35°C;
2.This series units used in low temperature conditions, 25% ethylene glycol to be used as a refrigerant;
3.Power supply: 3P-380V-50HZ;with voltage allowance ±10%,voltage dif between the phase lines±2%;
4.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;
5.There may be Changes for improvement without notice, confirm always before your order.
Remark:1.Designed Condition:Chilled Glycol in/out -1/-5°C; ambient 35°C;
2.This series units used in low temperature conditions, 25% ethylene glycol to be used as a refrigerant;
3.Power supply: 3P-380V-50HZ;with voltage allowance ±10%,voltage dif between the phase lines±2%;
4.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;
5.There may be Changes for improvement without notice, confirm always before your order.
Finished Products of Air Cooled Chiller:
Two Production Bases, Guarantee Supply Ability.
Famous Brand Enjoyed High Reputation overseas.